EasyManuals Logo

BONFIGLIOLI Active Cube User Manual

BONFIGLIOLI Active Cube
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #117 background imageLoading...
Page #117 background image
Function with direct synchronization
The drive accelerates the master speed with the ramps parameterized in the motion
block. When the motion block is started, the drive is synchronized with the master drive
directly. The master position is processed directly by the position controller.
The acceleration and deceleration for synchronizations follow an S
-curve.
The relative position cha
nge due to acceleration is compensated by the pos
i-
tion controller.
10/13
ACU
Modbus/TCP 115

Table of Contents

Other manuals for BONFIGLIOLI Active Cube

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BONFIGLIOLI Active Cube and is the answer not in the manual?

BONFIGLIOLI Active Cube Specifications

General IconGeneral
BrandBONFIGLIOLI
ModelActive Cube
CategoryInverter
LanguageEnglish

Related product manuals