11-5
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual System Programming
4) Enter the number of the week (First Week = 1 / Last
Week = 5) in that month that Summer Time ends.
dd =01
5) Enter the number of the day in the week (Sunday =
01 / Saturday = 07) Summer Time ends.
6) Use the [←] and [→] keys at any time to conrm
programming and then press [OK] to exit.
S YS TE M T IM E RS
System > Timers > L720
Exit Time
MENU 7-2-0
0 6 0
(*** System Wide Parameter ***)
SECONDS
This menu sets the exit time delay period for all areas on
the system. The exit timer starts when an area is armed in
the On and Part On modes. The keypad will sound an exit
warning tone while the exit timer is running. Exit delay
time can be programmed between 0 and 255 seconds.
1) Enter your Installer PIN + [MENU].
2) Enter [7] + [2] + [0] + [OK]. The keypad will display
the current Exit Time.
d =060
3) Using the numeric keys, enter the required Exit
Time in seconds. Valid times are 0 - 255 seconds 0 =
No Exit Time.
4) Press [OK] to save and exit or press [MENU] to exit
without saving.
System > Timers > L721
Entry Time 1
MENU 7-2-1
0 2 0
(*** System Wide Parameter ***)
SECONDS
This menu sets the entry time delay for zones programmed
as entry delay 1 zones. Entry Time 1 is common for all areas
on the system.
When a zone programmed as Delay 1 is triggered, the
entry time will start and the keypad will sound an entry
warning tone. Entry Time 1 can be programmed between
0 and 255 seconds.
1) Enter your Installer PIN + [MENU].
2) Enter [7] + [2] + [1] + [OK]. The keypad will display
the current Entry Time 1 delay.
d =020
3) Using the numeric keys, enter the required delay
for Entry Time 1 in seconds. Valid times are 0 - 255
seconds 0 = No Entry Time.
4) Press [OK] to save and exit or press [MENU] to exit
without saving.
System > Timers > L722
Entry Time 2
MENU 7-2-2
0 4 0
(*** System Wide Parameter ***)
SECONDS
This menu sets the entry time delay for zones programmed
as entry delay 2 zones. Entry Time 2 is common for all areas
on the system.
When a zone programmed as Delay 2 is triggered, the
entry time will start and the keypad will sound an entry
warning tone. Entry Time 2 can be programmed between
0 and 255 seconds.
1) Enter your Installer PIN + [MENU].
2) Enter [7] + [2] + [2] + [OK]. The keypad will display
the current Entry Time 2 delay.
d =040
3) Using the numeric keys, enter the required delay
for Entry Time 2 in seconds. Valid times are 0 - 255
seconds 0 = No Entry Time.
4) Press [OK] to save and exit or press [MENU] to exit
without saving.
System > Timers > L723
Part Entry Time
MENU 7-2-3
0 6 0
(*** System Wide Parameter ***)
SECONDS
This menu allows you to program the Part Mode Entry
Delay time also know as entry guard. When armed in Part
Mode, all active zones retain their normal functionality. ie.
instant zones will trigger instantly etc. The part entry timer
allows all active zones to have an entry delay when the
the area is armed in part mode regardless of their normal
functionality.This can help to prevent false alarms when
people on site inadvertantly unseal an active zone.
If a valid PIN code is not entered before the timer expires
then the alarm will trigger. Programming the entry guard
time as zero will disable this feature.