11-6
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual System Programming
1) Enter your Installer PIN +[MENU].
2) Enter [7] + [2] + [3] + [OK]. The keypad will display
the current Part Entry time.
d =060
3) Using the numeric keys, enter the required delay
for the Part Entry Time in seconds. Valid times are 0
- 255 seconds, 0 = No Part Entry Time.
4) Press [OK] to save and exit or press [MENU] to exit
without saving.
System > Timers > L724
Auto Arm Pre-Alert
MENU 7-2-4
0 1 0
(*** System Wide Parameter ***)
MINUTES
This menu allows you to program the Auto Arm Pre Alert
count down timer. The timer is used to warn sta or users
that the system is about to auto arm by sounding a tone
on the keypad. To set up auto arming see MENU 7-5-0 —
System Schedules.
If a valid PIN + [OFF] is entered, the tone will stop and the
keypad will prompt the user to either abort or delay the
automatic arming. If the user selects the option to delay
the auto arm, this sequence will repeat on the hour untill
the system is armed manually or automatically.
For example if the system is programmed to auto arm at
8.00pm and the Pre Alert time is set to 10 minutes then at
7.50pm the system will begin sounding the Pre Alert tone
on the keypad.
1) Enter your Installer PIN + [MENU].
2) Enter [7] + [2] + [4] + [OK]. The keypad will display
the current Pre-Alert Time.
d =010
3) Using the numeric keys, enter the pre-alert time .
Valid times are 0 to 255 minutes. 0 = No Auto Arm
Pre Alert.
4) Press [OK] to save and exit or press [MENU] to exit
without saving.
System > Timers > L725
Output Pre-Alert
MENU 7-2-5
0 0 0
(*** System Wide Parameter ***)
MINUTES
The panel can be programmed to automatically operate
an output via a schedule, see MENU 7-5-0 — System
Schedules.
This menu allows you to program the Output Pre Alert
count down timer. The timer is used to warn sta or users
that an output is about to operate by sounding a tone on
the keypad.
1) Enter your Installer PIN + [MENU].
2) Enter [7] + [2] + [5] + [OK]. The keypad will display
the current Output Pre Alert Time.
d =000
3) Using the numeric keys, enter the pre-alert time.
Valid times are 0 to 255 minutes. 0 = No Output Pre
Alert
4) Press [OK] to save and exit or press [MENU] to exit
without saving.
System > Timers > L726
Senior Watch Time
MENU 7-2-6
0 0 0
(*** System Wide Parameter ***)
HOURS
This feature can be used to verify that an elderly person
is OK or as a dead man timer for an onsite patrolman or
security ocer.
This menu allows you to program the Senior Watch Time
period. The panel must register at least one burglary zone
in the programmed area to unseal and reseal during this
time period or the panel will report a Senior Watch alarm
to the base station.
A Senior Watch Restore will be sent when at least one zone
is unsealed and resealed. Senior Watch monitoring is only
active when the corresponding area is in the disarmed
state.
1) Enter your Installer PIN + [MENU].
2) Enter [7] + [2] + [6] + [OK]. The keypad will display
the current senior watch time. (default = 0 hours).
d =000