3) Using the numeric keys, enter the new senior watch
time. Valid times are 0 to 255 hours. 0 = No Senior
Watch Time.
4) Press [OK] to save and exit or press [MENU] to exit
without saving.
S YS TE M PO WE R OP TI ON S
System > Power > L730
AC Options
MENU 7-3-0
1 Display AC Fail Y
2 Report AC Fail Y
3 Use AC To Synchronise The System Clock Y
4 Random AC Report 2hour N
5 AC Fail After 1 hour N
6 Reserved N
7 Reserved N
8 Display Clock Trouble Y
(*** System Wide Parameter ***)
This menu option allows you to congure the AC Mains
Power system options.
1) Enter your Installer PIN + [MENU].
2) Enter [7] + [3] + [0] + [OK].
The keypad will display the current options which are
selected or enabled.
-bit-
1 2 3 8
3) Use the numeric keys [1] to [8] to turn on and o
the features as required. When the corresponding
number on the keypad is on then the option is
selected.
4) When all options are programmed, press [OK] to
save and exit, or press [MENU] to exit without
saving.
Display AC Fail
Setting this option will cause the panel to ash the
Mains Power icon as soon as the AC power supply has
failed. If the power remains missing continiously for 1
minute then a system trouble will be registered on the
keypad. When the AC power supply returns to normal the
Mains Power icon will remain on steady. If this option is
disabled then the system will not ash the Mains Power
icon and no system trouble will occur.
Report AC Fail
Setting this option will cause the panel to report an
AC Fail to the base station if the mains power has been
missing for a period of 1 minute. A restore report will be
sent once the mains power has been restored for one
minute.
Synchronise System Clock to AC
Setting this option allows the panel to syncronise its
internal clock with the mains frequency (50hz). This
option should be set unless the panel is being used in an
area where the mains power is unreliable.
Random AC Reporting 2hr
Setting this option allows the panel to randomly delay
(up to 2 hours) the AC Fail report. This option is used to
prevent multiple Solution panels from reporting AC fail
at the same time.
AC Fail To 1 Hour
Setting this option will cause the panel to only send an
AC Fail report to the base station if the power has been
missing continuously for one hour. The Mains Power icon
will operate as normal.
Display Clock Trouble
Setting this option will cause the panel to show a
Date and Time System trouble if the power is removed
from the system for any period of time such as when
performing a system upgrade or service work. If this
option is disabled then no system trouble will appear
and you will need to remember to set the correct time
when you re power the system.
System > Power > L731
Battery Options
MENU 7-3-1
1 Display Battery Fail Y
2 Report Battery Fail Y
3 Execute Battery Testing On Arming Y
4 Arming Allowed On Low Battery Y
5 Reserved N
6 Reserved N
7 Reserved N
8 Reserved N
(*** System Wide Parameter ***)
This menu option allows you to congure the standby
Battery system options. The system is constantly
monitoring the battery condition with a dynamic battery
test carried out every 4 hours.
1) Enter your Installer PIN + [MENU].
2) Enter [7] + [3] + [1] + [OK].
The keypad will display the current options which are