11-8
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual System Programming
3) Use the numeric keys [1] to [8] to turn on and o
the features as required. When the corresponding
number on the keypad is on then the option is
selected.
4) When all options are programmed, press [OK] to
save and exit, or press [MENU] to exit without
saving.
Display Battery Fail
Setting this option will cause the keypad to display
a Trouble condition when the panel detects that the
standby battery is disconnected or that its voltage is low.
The trouble condition will clear as soon as the panel has
measured the battery voltage is 12.5 volts or greater.
Report Battery Fail
Setting this option will cause the panel to send a Low
Battery report to the base station when it measures
the battery voltage has dropped below 11.5 volts. A
Low Battery Restore report will be sent when the panel
detects that the battery voltage is above 12.5 volts.
If the panel fails to detect the battery, or if it measures
the battery voltage below 10.2 volts, then a Battery Test
Failed report will be sent. A Battery Test restore will be
sent when the battery is re-connected or replaced.
Execute Battery Testing On Arming
Setting this option will cause the panel to perform an
additional dynamic battery test each time Area 1 is
armed All On.
Arming Allowed On Low Battery
Setting this option will allow the system to be armed
even though the panel currently has a low battery
condition.
When this option is disabled, the panel will not arm
if there is a low battery condition or if the battery is
missing. The user will be notied of the system trouble
on the keypad and they will need to have the fault
rectied before the system or area can be armed.
System > Power > L732
Fuse Options
MENU 7-3-2
1 Display COMM+ Current Overload Y
2 Report COMM+ Current Overload Y
3 Display +12V (Acc) Current Overload Y
4 Report +12V (Acc) Current Overload Y
5 Display LAN+ Overload Y
6 Report LAN+ Overload Y
7 Reserved N
8 Reserved N
(*** System Wide Parameter ***)
This menu option allows you to congure the Fuse related
system options.
1) Enter your Installer PIN + [MENU].
2) Enter [7] + [3] + [2] + [OK].
The keypad will display the current options which are
selected or enabled.
-bit-
1 2 3 4 5 6
3) Use the numeric keys [1] to [8] to turn on and o
the features as required. When the corresponding
number on the keypad is on then the option is
selected.
Display COMM + Current Overload
Setting this option allows the keypad to display a system
trouble message when the current load on the COMM +
terminal exceeds its maximum rating of 3 Amps.
Report COMM + Current Overload
Setting this option will cause the panel to send an
Overcurrent Trouble report to the base station when
the current load on the COMM + terminal exceeds its
maximum rating of 3 Amps.
Display +12V (Accessories) Current Overload
Setting this option allows the keypad to display a system
trouble message when the current load on the +12 V
terminal exceeds its maximum rating of 1Amp.
Report +12V (Accessories) Current Overload
Setting this option will cause the panel to send an
Overcurrent Trouble report to the base station when the
current load on the +12 V terminal exceeds its maximum
rating of 1Amp.
Display LAN + Current Overload
Setting this option allows the keypad to display a system
trouble message when the current load on the LAN+
terminal exceeds its maximum rating of 1Amp.