11-14
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual System Programming
Emm=01
8) Enter the month (01 - 12) that the holiday will end.
9) Use the [←] and [→] keys to conrm programming
and then press [OK] to exit.
S YS TE M OP TI ON S
System > System Options > L770
General Options
MENU 7-7-0
1 Display LAN Fail Y
2 Report LAN Fail Y
3 Alarm On LAN Fail N
4 Cannot Change Own PIN N
5 Reserved N
6 Monitor Default PIN Codes N
7 PIN Always Required Y
8 Reserved Y
(*** System Wide Parameter ***)
This menu allows you to congure the General system
options. All options are global to users, areas and keypads.
1) Enter your Installer PIN + [MENU].
2) Enter [7] + [7] + [0] + [OK].
The keypad will display the current options which are
selected or enabled.
-bit-
1 2 7 8
3) Use the numeric keys [1] to [8] to turn on and o the
features as required. When the corresponding
number on the keypad is on then the option is
selected.
4) When all options are programmed, press [OK] to
save and exit, or press [MENU] to exit without
saving.
Display LAN Fail
Setting this option allows all connected keypads to
display a system trouble when a device connected the
the system LAN has failed to communicate to the panel.
Report LAN Fail
Setting this option allows the panel to report which LAN
device has failed to the base station.
Alarm On LAN Fail
Setting this option allows the panel to sound an
alarm when a device connected to the LAN failed to
communicate to the panel.
Cannot Change Own PIN
Setting this option prevents all users the ability to
change their own PIN.
Monitor Default PIN Codes
Setting this option will cause the panel to monitor the
default Installer PIN and User 1 PIN which are factory set
to 1234 and 2580 respectively. If either of these codes
are left as default then the keypad will display the system
trouble Default PIN. The fault will clear once the code or
codes have been changed.
PIN Always Required
Setting this option will force the system to request a
valid PIN to be entered before any menu functions can
be accessed. If this option is not set then some restricted
menu options will be available without entering a valid
PIN.
System > System Options > L771
Area Options
MENU 7-7-1
1 Area 1 = Common Area N
2 First To Open Last To Close N
3 Reset Siren All Users (All Areas) N
4 Power Up In Same State As Powered Down Y
5 Fault Acknowledge All Areas Y
6 Delay Trouble Beeps N
7 Power Up Disarmed N
8 Reserved N
(*** System Wide Parameter ***)
This menu allows you to congure the Area system
options. All options are global to users, areas and keypads.
1) Enter your Installer PIN + [MENU].
2) Enter [7] + [7] + [1] + [OK].
The keypad will display the current options which are
selected or enabled.
-bit-
4 5
3) Use the numeric keys [1] to [8] to turn on and o the
features as required. When the corresponding
number on the keypad is on then the option is
selected.
4) When all options are programmed, press [OK] to
save and exit, or press [MENU] to exit without
saving.