11-15
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual System Programming
Area 1 = Common Area
Setting this option will cause the system to automatically
arm Area 1 All On when all other areas have been turned
on. As soon as any area is turned o the system will
automatically turn Area 1 o. Only one common area is
available on the system. If no common area is required
then do not set this option.
First To Open / Last To Close
Setting this option will cause the system to only report
an opening signal to the base station when the rst area
is Disarmed and a closing signal when the last area has
been armed or turned All On.
Reset Siren All Users
Setting this option allows a user with a valid PIN to
silence alarm outputs from any keypad on the system
without the need to toggle the keypad to the area that
the alarm occurred.
If this option has not been programmed, the user will
need to toggle the keypad to the area the alarm occurred
in and then silence the alarm by entering their PIN
followed by the [OFF] key.
Power Up In Same State As Powered Down
Setting this option will cause the panel to power up
in the same state as it was when it was powerd down.
For example with this option set if the panel is in the
disarmed state and all power is removed for service
work to be done. When the power is reapplied, the
panel will start in the disarmed state. Any zone that was
programmed as bypassed when the power was removed
will remain bypassed when the power supply has
restored.
If this option is not programmed, the system will always
power up in the armed All On state and any zones
bypassed prior to power loss will power up as un-
bypassed zones.
Fault Acknowledge All Areas
Setting this option allow system trouble faults to be
acknowledged from any area or keypad on the system
without the need to toggle over to the area the fault
occurred in.
Delay Trouble Beeps
Setting this option will prevent any system trouble
events from sounding the keypad speaker between
the hours of 10pm until 7am. During this time, any new
trouble events will be shown in the keypad display.
If any trouble events are still in eect at 7am, the keypad
will begin sounding the trouble alert to notify the user
of the problem. The function is primarily for use in
residential installations.
Power Up Disarmed
Setting this option forces the control panel to power up
in the disarmed state after you power down the system.
System > System Options > L772
Keypad Idle Screen
MENU 7-7-2
(*** System Wide Parameter ***)
0 0
00 = No Idle Screen 02 = Time
01 = Date and Time 03 = Time + Temp Alternating
This menu allows you to sellect a keypad Idle Screen
which will appear on the display when there has been
no activity at the keypad for a period of 2 minutes. The
keypad display will return to normal as soon as any key
has been pressed.
The are two built-in Idle Screens and one custom Idle
screen which can be created and programmed only via
the Solution Link upload/download software. The custom
screen can be used to display the Installer name and logo
or other information as required.
All keypads on the system will display the same screen
saver. See the examples below.
1) Enter your Installer PIN + [MENU].
2) Enter [7] + [7] + [2] + [OK]. The keypad will display
the current Keypad Idle Screen option.
d= 0
3) Use the numeric keys to enter the new idle screen
option required, then press [OK] to save and exit or
press [MENU] to exit without saving.
System > System Options > L773
Keypad Hi/Lo Temp
-
MENU 7-7-3
0 0 ˚C 0 0 ˚C
(*** System Wide Parameter ***)
HI TEMP LO TEMP
The keypad Hi/Lo temperature allows you to program the
minimum (0 °C) and maximum (50 °C) temperatures the
keypad will monitor (tolerance = +/- 3 °C).
If the temperature falls below the minimum temperature,
or rises above the maximum temperature then the system
trouble indicator will be displayed.
1) Enter your Installer PIN or Master PIN + [MENU].
2) Enter [7] + [7] + [3] + [OK].
The keypad will display the current Hi temperature
setting.
hi=20