11-16
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual System Programming
3) Enter the required Hi temperature value in degrees
celcius.
LO=10
4) Enter the required Lo temperature value in degrees
celcius.
5) Press [OK] to save and exit, or press [MENU] to exit
without saving.
System > System Options > L774
Installer Options
MENU 7-7-4
1 Report/Log Entry/Exit Intstaller Menu N
2 Report/Log Program Data Change Y
3 Arm Only Installer PIN N
4 Reserved N
5 Auto Exit Installer Menu In 2 Hours Y
6 Auto Exit Service Mode In 2 Hours Y
7 Reserved N
8 Factory Defaulting Allowed Y
(*** System Wide Parameter ***)
This menu allows you to congure the Installer system
options.
1) Enter your Installer PIN + [MENU].
2) Enter [7] + [7] + [4] + [OK].
The keypad will display the current options which are
selected or enabled.
-bit-
2 5 6 8
3) Use the numeric keys [1] to [8] to turn on and o the
features as required. When the corresponding
number on the keypad is on then the option is
selected.
2) When all options are programmed, press [OK] to
save and exit, or press [MENU] to exit without
saving.
Report/Log Entry/Exit Installer Menu
Setting this option will cause the panel to make a log
entry and to send a report to the base station when the
installer enters and exits Installer programming mode.
The entry/exit reports will follow the System Route.
Report/Log Program Data Changed
Setting this option will cause the panel to make a log
entry and to send a report to the base station when
the installer has changed programming data. The data
changed reports will follow the System Route.
Arm Only Installer PIN
Setting this option will prevent the installer PIN holder
from disarming the system. Normally the installer PIN is
able to arm and disarm the system.
Auto Exit Installer Menu In 2 Minutes
Setting this option will cause the panel to automatically
terminate Installer programming mode after 2 minutes
of no activity on the keypad. If this option is not set, the
panel will remain in Installer programming mode until
manually terminated.
Auto Exit Service Mode In 2 Hours
Setting this option will cause the panel to automatically
terminate service mode after 2 hours of no activity
on the keypad keys. If this option is not set, the panel
will remain in the service mode until it is manually
terminated.
Factory Defaulting Allowed
Setting this option will allow the panel to be defaulted
back to the factory setting using the the on board push
button switch. See below for defaulting instructions.
If this option is not set then manual defaulting will not
function and the only way to default the panel will be by
using the current installer PIN. If the installer PIN is not
know then the panel will need to be returned to Digiex
for defaulting. A charge applies for this service.