11-18
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual System Programming
S YS TE M T ES T IN G
System > System Testing > L790
Walk Test All Zones
-
-
MENU 7-9-0
This menu allows you to test all zones within an area at
the same time. To successfully walk test each zone, you
must fault and restore each zone (eg. open, then close
front door etc).
1) Enter your Installer PIN or Master PIN + [MENU].
2) Enter [7] + [9] + [0] + [OK].
The keypad will display a list of all zones to be tested.
If your system is congured for multiple areas then
you may be prompted to select the area to test.
test
1 2 3 4 5 6 7 8
3) Fault and restore each zone that needs to be tested.
Any zone that has been successfully tested will no
longer be displayed on the keypad.
When all zones have been tested, the keypad will
display PASS.
PASS
4) Press [OK] to exit.
System > System Testing > Tst-bA
Battery Test
-
-
MENU 7-9-1
This menu allows you to manually test the systems back
up battery. The panel will automatically test the battery
once per day and every time Area 1 is turned All On.
The battery test can take up to two minutes to complete
and the keypad will display the voltage of the battery
during the test.
1) Enter your PIN + [MENU].
2) Enter [7] + [9] + [1] +[OK].
The keypad will display the battery voltage whilst
under test.
testing
If the test passes the keypad will display:
PAss
If the test fails the keypad will display. If this happens
you should contact your installer.
FAil
3) Press [OK] to exit.
» » E N D O F S E C T I O N « «