12-1
Bosch Security Systems 09/11 BLCC500I
S E C T IO N 12
Programming Examples
T
his section includes a number of programming examples detailling how to implement some common installation
functionality.
Examples are provided to show;
How to Open a Garage Door using a Single Digit Code.
How to Open a Garage Door using a 4 Button Keyfob.
How to set Auto Arming for an Area.
How to operate an Output using a Schedule
How to Use a Reader to Unlock a Door.
How to Use a Reader to Unlock a Door and Disarm Area 1.
How to Use a Reader to Unlock a Door and Arm/Disarm.
How to use Call Line Identication.
How to send SMS Reports.
Opening a Door using a Single Digit Code
The Solution 16i can be used to operate an electrically
controlled door using a single digit code. The example
assumes User 10 and Output 5 are being used. (Output 5
is located on the CM110B Output Expander).
Procedure
1) Set User Pin Code Length MENU 1-5-0 = 0
(0 = Variable Length)
2) Set User 10 - PIN Code MENU 1-1-2 = 5
3) Set User 10 - Area Assignment MENU 1-4-1 =
NNNNNNNN
4) Set Output 5 - Event Type MENU 4-1-1 = 56
(56 = Follow Pin)
5) Set Output 5 - Event Assignment MENU 4-1-2 = 10
(10 =User Number)
6) Set Output 5 - Output Polarity MENU 4-1-3 = 4
(4 = Normally Open One Shot Low)
7) Set Output 5 - Time Parameter MENU 4-1-4 = 000
000 005 000 (5 seconds)
8) Enable Output 5 - Output Options MENU 4-1-5 =
Display Status Message
Wire Output 5 to the appropriate Door Controller input.
Each time button 5 on the keypad is pressed the door will
activate.
Opening a Garage Door Using a 4 Button RF Keyfob
The following example show how to congure the
Solution 16i
to allow control of a grage door as well as
arm and disarm functions using a 4 Button Keyfob. The
example assumes User 10 and Output 5 are being used.
(Output 5 is located on the CM110B Output Expander).
Procedure
1) Set RF Receiver Type MENU 3-5-0 = D
(D = DS Type)
2) Assign Keyfob to User 10 MENU 1-3-0 = 123456789
3) Set Output 5 - Event Type MENU 4-1-1 = 53
(53 = RF Keyfob Function 1)
4) Set Output 5 - Event Assignment MENU 4-1-2 = 1
(1 =Area Number)
5) Set Output 5 - Output Polarity MENU 4-1-3 = 4
(4 =Normally Open One Shot Low)
6) Set Output 5 - Time Parameter MENU 4-1-4 = 000
000 005 000 (5 seconds)
7) Enable Output 5 - Output Options MENU 4-1-5 =
Display Status Message.