6-8
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual Area Programming
Arm/Disarm Flash Via RF Keyfob
When slected, the panel will activate the strobe output
for six seconds when a user turns the area on via an RF
Key fob. This provides silent feedback to the user that the
signal has been received.
Arm/Disarm Flash Via Keyswitch or PGM Input
When selected, the panel will activate the strobe
output for six seconds when a user turns the area on
via a Keyswitch Input or the Programmable Input. This
provides silent feedback to the user that the signal has
been received.
24-Hour Alarm
When selected, the panel will activate the strobe output
when a zone programmed as 24-hour (audible or silent)
has registered an alarm. Zones programmed as 24-Hour
Hold-Up are not included.
A RE A R E PO RT ING
Areas > Reporting > L220
Account Dest 1
MENU 2-2-0
0 0 0 0 0 0 0 0 0 0
The area account number identies which control panel is
reporting to the security company’s base station receiver.
Each destination can have a dierent account number
programmed. The number should be entered from left to
right with trailing zeros.
1) Enter your Installer PIN + [MENU].
2) Enter [2] + [2] + [0] + [OK].
3) Enter the area required, then press [OK].
4) Using the numeric keys, enter the new account
number. Use the up and down arrows to select
special characters BCDEF.
000000
5) Press [OK] to save and exit or press [MENU] to exit
without saving.
Areas > Reporting > L221
Account Dest 2
MENU 2-2-1
0 0 0 0 0 0 0 0 0 0
The area account number identies which control panel is
reporting to the security company’s base station receiver.
Each destination can have a dierent account number
programmed. The number should be entered from left to
right with trailing zeros.
1) Enter your Installer PIN + [MENU].
2) Enter [2] + [2] + [1] + [OK].
3) Enter the area required, then press [OK].
4) Using the numeric keys, enter the new account
number. Use the up and down arrows to select
special characters BCDEF.
000000
5) Press [OK] to save and exit or press [MENU] to exit
without saving.
Areas > Reporting > L222
Open / Close Route
MENU 2-2-2
(*** System Wide Parameter ***)
0 1
00 = Report Events To Log Only
01 = Report Events To Destination 1 + Log
02 = Report Events To Destination 2 + Log
03 = Report Events To Destination 1 & Destination 2 + Log
04 = Report Events To Dest 2 If Dest 1 Fails + Log
This menu programs the destination for open and close
reports. Only one option can be programmed in this
menu.
1) Enter your Installer PIN + [MENU].
2) Enter [2] + [2] + [2] + [OK].
3) Use the numeric keys 0-9 to select the desired
option.
D= 1
4) Press [OK] to save and exit or press [MENU] to exit
without saving.
A RE A T ES TI NG
Areas > Area Testing > L290
Area Watch
MENU 2-9-0
0 1 2
(*** System Wide Parameter ***)
WEEKS
This menu programs the number of weeks (001 255
weeks / 000 = disabled) an area can remain disarmed
before registering an ‘Inactivity Interval’ report. A restore
signal will be sent when the area is next armed and the
exit time expires.
1) Enter your Installer PIN + [MENU].