6-9
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual Area Programming
2) Enter [2] + [9] + [0] + [OK]. The keypad will display
the current number of weeks programmed for area
watch.
d= 012
3) Using the numeric keys, enter the number of weeks
that an area can remain turned o betore a trouble
condition will occur. Valid entries are 1 – 255 Weeks
or 000 to disable.
4) Press [OK] to save and exit or press [MENU] to exit
without saving.
Areas > Area Testing > L291
User Test Interval
MENU 2-9-1
0 0 0
(*** System Wide Parameter ***)
DAYS
This menu sets the number of days before it will prompt the
user to walk test the system. To clear the trouble condition,
you will need to perform the ‘Walk Test’ function.
1) Enter your Installer PIN + [MENU].
2) Enter [2] + [9] + [1] + [OK]. The keypad will display
the current number of weeks between User Test
intervals.
d= 000
3) Using the numeric keys, enter the number of days
between each user test interval. Valid entries are 1
– 255 Days or 000 to disable.
4) Press [OK] to save and exit or press [MENU] to exit
without saving.
Areas > Area Testing > L292
Service Interval
MENU 2-9-2
0 0 0
(*** System Wide Parameter ***)
WEEKS
This menu sets the number of weeks between service
intervals. When a service interval is due, a trouble condition
will display on the keypad to remind the customer that a
system check is required by the security company. When
viewing the trouble condition, the keypad will display ‘Call
For Service’. To clear the trouble condition, the installer
must enter and exit installer’s programming mode.
1) Enter your Installer PIN + [MENU].
2) Enter [2] + [9] + [2] + [OK]. The keypad will display
the current number of weeks between user test
intervals.
d= 000
3) Using the numeric keys, enter the number of weeks
between each user Service Interval. Valid entries
are 1 – 255 Weeks or 000 to disable.
4) Press [OK] to save and exit or press [MENU] to exit
without saving.
Areas > Area Testing > L293
Test Options
MENU 2-9-3
1 User Test Interval Y
2 Reserved N
3 Reserved N
4 Reserved N
5 Reserved N
6 Walk Test Reports Y
7 Walk Test 24-Hour Zones N
8 Walk Test Fire Zones N
The above options are programmable per area.
1) Enter your Installer PIN + [MENU].
2) Enter [2] + [9] + [3] + [OK] and enter the area
required, then press [OK].
3) Use keys [1] to [8] to toggle on or o the test report
options required.
-Bit-
1 6
4) Repeat Step 3 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
User Test Required
This option allows the keypad assigned to the
corresponding area to display a trouble condition when a
user test is due. The trouble condition can be cleared by
performing a walk test.
Walk Test Reports
This option allows the corresponding area to send Walk
Test reports when a user enters/exits walk test mode and
test zones.