7-3
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual Input Programming
3) To bypass a zone, enter the zone number and then
press [OK] .
The zone indicator will begin to ash. To un-bypass a
zone type the zone number and then press [OK].
Repeat step 3 for any additional zones that you need
to bypass or un-bypass.
4) Press [OK] to save and exit, or press [MENU] to exit
without saving.
i
Note
You can only bypass zones in the current area.
To bypass zones in another area, exit progamming
mode and move to the required area before
repeating from step 1.
i
Note
You can also access the Zone Bypass function by
entering your PIN and then pressing the PART /
Bypass key down for 2 seconds.
Inputs > Commands > ch-Zn
Set Chime Zones
-
MENU 3-0-3
This menu allows the Master User or Installer to program
zones to be monitored when the corresponding area is
turned o. Chime mode is ideal to monitor a front door to
sound the keypad buzzer when opened (faulted).
1) Enter your Installer PIN or Master PIN + [MENU].
2) Enter [3] + [0] + [3] + [OK].
The keypad will ash the Zn= prompt, indicating
that you are in data entry mode. Any zone(s) which
are currently set as Chime Zones will be displayed.
An area icon will also display to verify which area you
are programming chime zones for.
Zn=
1
1 3
3) Enter the zone number (1 to 16) followed by the [OK]
key to toggle the zone on or o for chime mode.
Repeat step 3 toggle chime zones on or o.
4) Press [OK] to save and exit, or press [MENU] to exit
without saving.
Inputs > Commands > Pt2-Zn
Set Part 2 Zones
-
MENU 3-0-4
This menu allows you to program which zones are to be
monitored when an area has been turned Part 2 On.
At factory default all zones are monitored when you turn
the area Part 2 On.
1) Enter your Master PIN or Intsaller PIN + [MENU].
2) Enter [3] + [0] + [4] + [OK].
The keypad will display the Zn= prompt.
Any zone(s) that are programmed not to be monitored
when you turn the area Part 2 On will not be displayed.
An area icon will also display to verify which area you
are programming chime zones for.
Zn=
1
1 2 3 5 7 8
3) Enter the zone number (1 to 16) followed by [OK] to
toggle the monitoring of the zone on or o when
turned Part 2 On.
Repeat Step 3 for any additional Part 2 zones you
require.
4) Press [OK] to save and exit, or press [MENU] to exit
without saving.
i
Note
In the above example, zones 1, 2, 3, 5, 7 and 8 will be
monitored when the Area 1 is turned Part 2 On.
Zones 4 and 6 will not be monitored.
Inputs > Commands > Fire-r
Smoke Sensor Reset
-
-
MENU 3-0-5
If your system has smoke sensors tted, they may be
powered directly by the control panel. If this is the case,
this menu is used to reset your smoke detectors when
required.
1) Enter your PIN + [MENU].
2) Enter [3] + [0] + [5] + [OK].
Busy
The keypad will display the word BUSY for 10 seconds
while the smoke sensors are reset before returning to
the menu.
i
Note
If the system is congured for multiple areas you
may be asked to select the area to reset.