7-8
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual Input Programming
3) Now select the output that will be used to operate
the door strike and assign it to Access Group 5. You
also need to set the output type to ACCESS and the
polarity to one shot low with a time of how long
you would like the strike to operate. Generally a
strike would be operated for 5 seconds.
4) Assign the Reader under Reader properties to
Access Group 5.
When a user who belongs to Access Group 5 presents their
token to the reader that is assigned to Access Group 5, the
assigned output will operate releasing the door strike.
A reader can belong not only to a Access Group but also
to an Area if arming and disarming is required from the
reader.
If a user presents their token to an reader that has an
area assigned, then the user Access Group and Area
Permissions are both checked. If the area is armed and the
user belongs to the same area as the Reader and the same
Access Group, the system will disarm and allow access.
If the user does not belong to the same area as the reader
but the Access Groups match, then door access will only
be available to that user if the area is disarmed.
When using the same reader for door access as well as arming,
you need to select the badging option MENU 1-6-3 Reader
Options. Badging requires that you present your token 3
times in succession within 5 seconds to arm the system.
Inputs > Zone Properties > L315
Access Group
MENU 3-1-5
0 0
00 = No Access Group
01 = Access Group 1 05 = Access Group 5
02 = Access Group 2 06 = Access Group 6
03 = Access Group 3 07 = Access Group 7
04 = Access Group 4 08 = Access Group 8
1) Enter your Installer PIN + [MENU].
2) Enter [3] + [1] + [5] + [OK], then enter the zone
required and press [OK]. The keypad will display
the current Access Group setting.
d= 0
3) Using the numeric keys, enter the Access Group
that you want to assign the zone to.
4) Press [OK] to save and exit or press [MENU] to exit
without saving.
Inputs > Zone Properties > L316
Report Route
MENU 3-1-6
0 1
00 = Report Events To Log Only
01 = Report Events To Destination 1 + Log
02 = Report Events To Destination 2 + Log
03 = Report Events To Destination 1 & Destination 2 + Log
04 = Report Events To Dest 2 If Dest 1 Fails + Log
This menu sets the Zone Report Route or Report
Destination for each individual zone in the system. All
events such as alarms and troubles for each zone will be
reported according to this menu setting. Each zone can
only be assigned to one report route from the list above.
1) Enter your Installer PIN + [MENU].
2) Enter [3] + [1] + [6] + [OK], then enter the zone
number required and press [OK]. The keypad will
display the current Zone Report Route.
d= 0
3) Use the numeric keys to program the Report Route
that you want to assign the zone to.
4) Press [OK] to save and exit or press [MENU] to exit
without saving.
i
Note
At factory default all Zones are set to report to
Destination 1 and the System Log. See the Zone
Default Table for more information on Zone default
settings.
Inputs > Zone Properties > L317
Report Options
MENU 3-1-7
1 Lockout Dialler Y
2 Report Alarm Y
3 Report Trouble Y
4 Report Bypass Y
5 Reserved N
6 Reserved N
7 Report Restores Y
8 Delay Report N
The above options are programmable per zone.
1) Enter your Installer PIN + [MENU].
2) Enter [3] + [1] + [7] + [OK], then enter the zone
number required and press [OK]. The keypad will
display the Report Options for the currently
selected zone.