7-7
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual Input Programming
Inputs > Zone Properties > L313
Pulse Count
MENU 3-1-3
0 0
PULSES
00 = 0 Pulse 08 = 8 Pulses
01 = 1 Pulse 09 = 9 Pulses
02 = 2 Pulses 10 = 10 Pulses
03 = 3 Pulses 11 = 11 Pulses
04 = 4 Pulses 12 = 12 Pulses
05 = 5 Pulses 13 = Delay (By Seconds)
06 = 6 Pulses 14 = Delay (By Minutes)
07 = 7 Pulses 15 = Delay (By Hours)
Pulse Count sets the number of trigger pulses a single
zone must receive before an alarm will be tripped. The
number of pulses must be detected within the Pulse
Count Time period for an alarm to occur. See MENU 3-1-4
— Pulse Count Time.
A feature called Pulse Count Handover can be enabled
allowing pulses registered by one zone to handover to
another zone provided they are the same Zone Type (ie.
instant zone to instant zone) and in the same Area. See
MENU 2-1-2 — Input Options
When pulse count hands over from one zone to another
and an alarm is triggered, a cross alarm report will be sent
to the central station.
Options 13 to 15 program how long a zone must be
faulted (delay time) before the zone will register an alarm
condition. This delay time is calculated by multiplying the
pulse count delay option (Second, Minutes or Hours) with
the pulse count time set in MENU 3-1-4.
1) Enter your Installer PIN + [MENU].
2) Enter [3] + [1] + [3] + [OK] and enter the zone
number required, then press [OK].
d= 00
3) Using the numeric keys, enter the number of pulses
required to register an alarm. Valid entries are 0 –
15.
4) Press [OK] to save and exit or press [MENU] to exit
without saving.
Inputs > Zone Properties > L314
Pulse Count Time
MENU 3-1-4
1 2 0
SECONDS
This menu sets the time period during which the number
of zone trigger pulses must be received for an alarm to
occur. The zone must be set as a Pulse Count Zone for this
time to have any eect.
1) Press your Installer PIN + [MENU].
2) Enter [3] + [1] + [4] + [OK], then enter the zone
required and press [OK].
d= 120
3) Using the numeric keys, enter the required Pulse
Count Time.
Valid entries are 0 – 255 seconds.
4) Press [OK] to save and exit or press [MENU] to exit
without saving.
U ND ER STAND IN G ACC ES S GR OU PS
Access Groups are used to link Readers, Users and Outputs
together to allow you to operate a door strike when a user
token is presented to a given reader. To do this you need
to create an access group and assign the user, the reader
and the output to the same access group.
Users
A user can belong to multiple Access Groups.
Outputs
An output can only belong to 1 Access Group.
Reader
A reader can belong to only 1 Access Group.
Access Group
There are 8 dierent access groups.
Door Access Group Example
1) To set up a door access group you need to select an
unused Access Group number from 1 to 8, in this
example we will assume the Access Group number
to be 5.
2) Under user properties assign the users who you
wish to have access to Access Group 5. Remember
that you are able to assign users to more than one
Access Group.