6 Burglary 24-Hour
Zones programmed as 24-hour burglary will trigger an
alarm as soon as the zone becomes faulted regardless
of what state the area is in. 24-Hour zones are active 24
hours a day. A 24hr Burglary report will be sent to the
central station receiver.
7 Tamper 24-Hour
Zones programmed as 24-Hour Tamper will trigger an
alarm as soon as the zone becomes faulted regardless
of what state the area is in. 24-Hour zones are active 24
hours a day. A 24hr Tamper report will be sent to the
central station receiver.
8 Hold Up 24-Hour
Zones programmed as 24-Hour Hold Up will trigger
a Silent alarm as soon as the zone becomes faulted
regardless of what state the area is in. 24-Hour zones are
active 24 hours a day. A 24hr Hold Up report will be sent
to the central station receiver. No Siren/Strobe or Keypad
indication will be given. To view the status of a 24hr hold
up zone, refer to MENU 3-0-1.
9 Medical 24-Hour
This zone type is used for personal medical emergency
alarms. Zones programmed as 24-Medical will trigger an
alarm as soon as the zone becomes faulted regardless
of what state the area is in. A 24hr Medical report will be
sent to the central station receiver.
10 Panic 24-Hour
This zone type is used for a general type of emergency
including the presence of one or more unwanted persons
trying to gain entry to the premises. It will sound an
alarm at any time as soon as the zone becomes faulted
regardless of what state the area is in. A 24hr Panic report
will be sent to the central station receiver.
11 Fire 24-Hour
This zone type is used for Fire and Smoke detector
alarms. Zones programmed as 24hr Fire will trigger an
alarm as soon as the zone becomes faulted regardless of
what state the area is in. A 24hr Fire report will be sent to
the central station receiver.
If a horn speaker is connected and programmed, a
distinct re sound will be heard to indicate that it is a re
alarm that has registered. The re sound via the horn
speaker is dierent than the burglary sound.
13 Keyswitch
A keyswitch zone can be used as an input terminal to
turn on and/or o an area. Refer to MENU 3-4-1 —
Keyswitch Options to select the various options such as
latching or momentary arm and/or disarm etc. When
reporting back to base, the keyswitch user number will
follow the actual zone number.
14 Display Only
A display zone is not a burglary zone. It can never sound
the sirens or trigger the dialler. Its purpose is to only
display on the keypad when faulted.
15 24-Hour Non Burglary
This zone type operates as a 24-hour type and is used for
non-specic alarms such as water level or temperature
sensors.
i
Note
The 24 Hour Zone Types listed above are active 24hrs
a day. They will trigger an alarm regardless of
whether or not the system or area is in the Armed,
Part Armed or Disarmed state.
Inputs > Zone Properties > L312
Area Assignment
MENU 3-1-2
0 1
00 = No Area
01 = Area 1 03 = Area 3
02 = Area 2 04 = Area 4
This menu programs which area or partition each zone
belongs to. The system can be partitioned to a maximum
of 4 separate areas. Each zone can only be assigned to a
single area. For installations requiring a common access
point, it is possible to set Area 1 to be a common area. See
MENU 7-7-1 — Area Options
1) Enter your Installer PIN + [MENU].
2) Enter [3] + [1] + [2] + [OK] and enter the zone
number required, then press [OK].
d= 01
3) Use the numeric keys, enter the area that you want
to assign the zone to.
4) Press [OK] to save and exit or press [MENU] to exit
without saving.

Table of Contents