9-9
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual Comms Programming
‘Log Overow report. The panel will also log these events
in its memory.
1) Enter your Installer PIN + [MENU].
2) Enter [5] + [3] + [2] + [OK]. The keypad will display
the current threshold limit. The default is 70% full.
d= 070
3) Using the numeric keys enter the new threshold
limit, then press [OK] to save and exit or press
[MENU] to exit without saving. There is no need to
enter the % symbol.
i
Note
Each time a Solution Link RAS session is established
with the panel, the log information will be uploaded
to the Solution Link database where it can be
reported on or archived for later use
Comms > Remote Access > L533
Ring Count
MENU 5-3-3
00 = No Answer 2 0
01 to 30 = Answer Ring Count
This menu sets the number of rings the panel will wait
until answering an incoming call. Programming a zero will
stop the panel from answering any incoming calls.
1) Enter your Installer PIN + [MENU].
2) Enter [5] + [3] + [3] + [OK]. The keypad will display
the current ring count.
d= 020
3) Use the numeric keys to enter the required ring
count, then press [OK] to save and exit or press
[MENU] to exit without saving.
i
Note
If answering machine bypass is required to allow a
Solution Link connection to be made without the
answering machine answering the call, see MENU
5-3-4 — Solution Link RAS Options
Comms > Remote Access > L534
Solution Link RAS Options
MENU 5-3-4
1 RAS Allowed Y
2 Call Back Verication Required N
3 Terminate RAS on Alarm Y
4 Answer Machine Bypass Y
5 Answer Incoming Call Only If Armed N
6 Tone Bypass Y
7 Allow User Functions Via Remote Access Software Y
8 Report / Log RAS Start / End Sessions Y
1) Enter your Installer PIN + [MENU].
2) Enter [5] + [3] + [4] + [OK]. The keypad will display
the current RAS options.
-Bit-
1 3 4 6 7 8
3) Use the numeric keys [1] to [8] to toggle on or o
the option required.
4) Repeat Step 3 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
RAS Allowed
This option allows you to congure the panel via the
Solution Link RAS upload/download software using a PC.
There are two dierent methods of connection avialable;
1) Direct Connect – via serial cable.
2) Remote Connect – via telephone line.
i
Note
See Direct Link and Solution Link RAS Upload/
Download programming in Section 5
Programming Overview for more information.
Call Back Verification Required
Setting this option will force the panel to use call back
verication for all remote Solution Link RAS sessions. See
MENU 5-3-0 — Call back Number for more information.
Terminate RAS On Alarm
If this option is programmed, the RAS connection
between the panel and the remote upload / download
computer will be terminated if panel registers an alarm
that needs to be reported.
Answer Machine Bypass
Answering machine bypass allows you to establiish a
RAS connection to a panel when there is an answering
machine or facsimile machine connected on the same
telephone line.