Rate:
Unreferenced
PID:
Enable or disable alarming of Unreferenced PID errors.
SDT: Enable or disable alarming of Service Description Table errors.
Only relevant when DVB mode is selected.
SDT - Maximum
interval Actual
(ms):
The maximum allowed section repetition interval for the SDT
Actual table.
Default: 2 000 ms
SDT - Maximum
interval Other
(ms):
The maximum allowed section repetition interval for the SDT
Other table.
Default: 10 000 ms
SDT - Minimum
gap interval
(ms):
The minimum allowed section gap interval for the SDT table.
Default: 25 ms
SDT - Verify
SDT against
PAT:
If enabled an alarm will be generated if a service found in the
PAT is not listed in the SDT.
Default: Disabled
SDT - Require
service name:
If enabled an alarm will be generated if a service found in the
PAT does not have a service name or if the service name is
empty.
Default: Disabled
SDT - Require
BAT Presence:
If enabled an alarm will be generated if BAT is not present in the
stream.
Default: Disabled
EIT: Enable or disable alarming of Event Information Table errors.
Only relevant when DVB mode is selected.
EIT - Maximum
interval Actual
(ms):
The maximum allowed section repetition interval for the EIT
Actual table.
Default: 2 000 ms
EIT - Minimum
gap interval
(ms):
The minimum allowed section gap interval for the EIT tables.
Default: 25 ms
EIT - Required
Table IDs:
If one or more table IDs are specified an alarm will be generated
if these table IDs are not present in the stream on the EIT PID.
Entries should be separated by commas, or a range may be
specified. Example: '78,79,80-85'
Default: Disabled
PROBE USERS' MANUAL VERSION 5.0
2014 © BRIDGE Technologies Co AS - Bentsebrugata 20 - N-0476 Oslo, Norway - tel: +47 22 38 51 00 -
www.bridgetech.tv
149