Default: 30000ms
ATSC EIT: Enable or disable alarming of ATSC Event Information Table
errors.
Only relevant when ATSC mode is selected.
ATSC EIT -
Maximum
interval EIT-0
(ms):
The maximum allowed section repetition interval for the ATSC
EIT-0 table.
Default: 500ms
EIT - Maximum
interval EIT-1 to
EIT-3 (ms):
The maximum allowed section repetition interval for the ATSC
EIT-1 to EIT-3 tables.
Default: 5000ms
EIT - Maximum
interval EIT-4 to
EIT-127 (ms):
The maximum allowed section repetition interval for the ATSC
EIT-4 to EIT-127 tables.
Default: 30000ms
ETT: Enable or disable alarming of Extended Text Table errors.
Only relevant when ATSC mode is selected.
ETT - Maximum
interval ETT-0
(ms):
The maximum allowed section repetition interval for the ATSC
ETT-0 table.
Default: 2000ms
ETT - Maximum
interval ETT-1
to ETT-3 (ms):
The maximum allowed section repetition interval for the ATSC
ETT-1 to ETT-3 tables.
Default: 5000ms
ETT - Maximum
interval ETT-4
to ETT-127
(ms):
The maximum allowed section repetition interval for the ATSC
ETT-4 to ETT-127 tables.
Default: 30000ms
STT: Enable or disable alarming of System Time Table errors.
Only relevant when ATSC mode is selected.
STT - Maximum
interval (ms):
The maximum allowed section repetition interval for the STT
table.
Default: 1000ms