The COFDM threshold parameters are:
COFDM threshold - Edit:
Name: A text field describing the threshold template
Pre FEC BER: Threshold level for bit error ratio before forward error
correction
Post FEC BER: Threshold level for bit error ratio after forward error
correction
Minimum MER: Threshold level for calculated modulation error ratio
Minimum signal to
noise ratio:
Threshold level for signal to noise ratio (dB)
Minimum signal
strength:
Threshold level for minimum signal strength.
This is a measure of the stream signal power. It is expressed
according to the level mode selection made in the Setup -
ETR view:
dBm: in decibels relative to a reference value of 1mW
dBuV: in decibels relative to a reference value of 1µ V
dBmV: in decibels relative to a reference value of 1mV
Maximum signal
strength:
Threshold level for maximum signal strength.
This is a measure of the stream signal power. It is expressed
according to the level mode selection made in the Setup -
ETR view:
dBm: in decibels relative to a reference value of 1mW
dBuV: in decibels relative to a reference value of 1µ V
dBmV: in decibels relative to a reference value of 1mV