Multi-edit functionality allows editing several VBC thresholds simultaneously. Highlight
the list entries that should be edited and click the Edit selected button.
VBC thresholds
Name: The name of the VBC threshold template
No signal: Number of seconds with 'No signal'
RTP error: Number of seconds with RTP packet drops. This measurement
will be zero unless the stream is encapsulated in RTP headers
MLR error: Number of seconds with packet drops in the TS layer (seconds
when media loss rate is non-zero). This is equal to the number
of error seconds with CC errors.
IAT error: Number of seconds when the inter-packet arrival time exceeds
the threshold
Max bitrate
error:
Number of seconds the bitrate can exceed the error-threshold
before a VBC alarm is generated
Min bitrate error: Number of seconds the bitrate can fall below the error-
threshold before a VBC alarm is generated
ETR Pri 1 errors: Number of seconds with ETSI TR 101 290 Priority 1 alarms