EasyManua.ls Logo

BridgeTech VB20 - Page 60

BridgeTech VB20
261 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Post FEC
BER:
Bit error rate after Viterbi FEC
above specified threshold
Default: Enabled, severity
Major
MER: Modulation Error Ratio above
specified threshold
Default: Enabled, severity
Major
SNR: Signal to Noise Ratio below
specified threshold
Default: Enabled, severity
Major
Signal
strength:
Signal strength below specified
threshold
Default: Enabled, severity
Major
SFN meas: Measurements to do with DVB-T/T2
SFN networks
Default: Enabled, severity
Major
Packet error
count:
Detection of one or more errored
packets after demodulator FEC
Default: Enabled, severity
Major
Centre
frequency:
Difference between received and
configured RF frequency exceeds
speficied threshold (VB262, VB252)
Default: Enabled, severity
Major
Symbol rate: Difference between received and
configured symbol rate exceeds
specified threshold (VB262)
Default: Enabled, severity
Major
Post BCH
FER:
DVB-T/T2 BCH Frame Error Rate
exceeds speficied threshold
(VB252)
Default: Enabled, severity
Major
Interface
overflow:
Input interface overflow error Default: Enabled, severity
Major
SYS (system) events
[Critical
system
errors]:
Enable this to view all critical
system errors
Default: Enabled, severity
Fatal
[System
errors]:
Enable this to view all system
errors
Default: Enabled, severity
Major
[System
info]:
Enable this to view system
information messages
Default: Enabled, severity OK
OTT alarms
The number
of profiles
changed:
The number of profiles flagged in
the manifest file changed
Default: Enabled, severity
Warning
Download The download duration time Default: Disabled, severity