4-7-10. Replacing the bobbin
1. Press the BOBBIN switch while the machine is in sewing standby mode. The presser foot will be
lowered and the X-Y feed mechanism will be retracted.
2. Open the module and replace the bobbin.
3. Close the module, and then press the RESET switch. The X-Y feed mechanism will move back to the
sewing start position and the presser foot will be raised.
Refer to "4-4. Bobbin case installation and threading" on page 26.
4-7-11. Altering the production counter value
If the () SELECT switch is pressed while the machine is in sewing standby mode, the production
counter value will increase by 1. If the ( ▼) SELECT switch is pressed, the production counter value will
decrease by 1.