2.2 Parts Life Reset Function
This function is used to reset the relevant part counter when the user replaced a periodical
replacement part with the correct procedure, and also used to forcibly reset the relevant part
counter when an error cannot be resolved because the user did not replace a consumable
part with the correct procedure.
(1) Press the 3 and 9 buttons at the same time in the ready state.
(2) The “Reset Menu” will appear on the LCD. Select the applicable periodical replacement
part or consumable part by pressing the or button and press the OK button.
<Periodical replacement parts or consumable part are indicated on the LCD>
•Drum
(3) Once “1.Reset 2.Exit” appears on the LCD; press the 1 or 2 button.
(4) The machine implements clearing the counter.
2.3 Deletion of User Setting Information, etc.
In this machine, the user setting information is stored in the EEPROM and flash memory of
the main PCB ASSY. You can delete all the data listed below at a time with the procedure
given below.
• Information related to Net
• User setting information
<Operating Procedure>
(1) Press the Menu button while the machine is in the ready state.
(2) Press the or button, then the “Initial Setup” or “General Setup” will appears on the
LCD and press the OK button.
(Which will appear, “Initial Setup” or “General Setup”, depends on the model.)
(3) Press the or button, then the “Reset Menu” will appear on the LCD and press the
OK button.
(4) Press the or button, then the “All Settings” will appear on the LCD and press the
OK button.
(5) The “1.Reset 2.Exit” appear on the LCD.
(6) Press the 1 button, and the user setting information is deleted, and the machine goes
back to the ready state.
Note:
• This function is not available on models without the numeric keys.
• All replacement parts are always indicated on the LCD even though their lives do not
reach the end of life.
• The machine returns to the ready state automatically if no panel operation is
implemented for 30 seconds.