2-83
Confidential
â– Error code C700
The memory is insufficient to expand the data of PC-Print.
Error code C800
The memory used to store secure print data exceeded the memory size for secure print data.
< User Check >
- Print the print data stored in the memory.
- Divide the print data and print it.
â– Error code D100
An error occurred during modem initialization.
Error code D200
The machine detected that the modem PCB was disconnected.
Out of Memory
Press Stop Key
Print Data Full
Print Data is full. Press Stop[X] Key and delete the previously stored data.
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Print Unable D1
Turn the power off and then back on again.
Machine Error
-
Step Cause Remedy
1 Connection failure of the modem
PCB flat cable
Reconnect the modem PCB flat cable.
2 Modem PCB failure Replace the modem PCB ASSY.
3 Main PCB failure Replace the main PCB ASSY.