2-14
Confidential
050C When the temperature of the
center thermistor of the fuser
unit is higher than the idle
temperature, the side thermistor
of the fuser unit detected a
temperature lower than the
specified value.
2-42
050D ---
050F ---
0600 ---
0700 ---
0800 Error occurred in the internal
temperature sensor.
2-43
0900 Machine detected more than
100 times that supplied power
was unstable.
2-43
0A01 The blower failure was detected. 2-43
0A02 The fuser fan failure was
detected.
2-44
0B01 Error occurred in the
high-voltage power supply PCB
ASSY while the machine is in
operation.
2-44
0B02 Error occurred in the
high-voltage power supply PCB
ASSY in the ready state.
2-44
0C00 Error occurred in the density
sensor.
2-44
0D01 ---
0D02 ---
0D03 ---
0D04 ---
0E00 Communication error occurred
in the high-voltage power supply
PCB ASSY.
2-45
1003 The registration mark sensor R
is dirty and cannot normally
receive reflected light.
2-45
Error
Codes
Description
Refer
to:
1004 The registration mark sensor L
is dirty and cannot normally
receive reflected light.
2-45
1100 ---
1200 ---
1300 ---
1400 Condensation occurred in the
machine.
2-46
1500 Error occurred in the paper eject
origin sensor.
2-46
1C00 The reading signal of the
EEPROM of the laser unit
cannot be detected.
2-46
1D01 ---
1D02 ---
1D03 ---
1D04 ---
1E01 ---
1E02 ---
2001 ---
2002 ---
2003 ---
2004 ---
2005 ---
2006 ---
2101 ---
2102 ---
2103 ---
2104 ---
2105 ---
2201 ---
2202 ---
2203 ---
2204 ---
2205 ---
2206 ---
2207 ---
Error
Codes
Description
Refer
to: