T419S Indicator Service Manual 47
6.3 System menu
Auto Choices under this are on, PwrUp and Off. Choose On (the default
setting) and the indicator will update anytime it receives an update via
Zcom. Choose PwrUp to have the indicator auto-update on powerup if an
update is available. Choose Off to turn auto-update off.
6.3.10 Password
Use this to change the password for the Admin, Diag and Calib menus.
6.3.11 Z-Lock
This stands for zero lock. Use this to enable and configure the zero lock feature during
an automated weighing process. When enabled, if the scale does not achieve a stable,
gross zero condition some time within X minutes (the time you configure), then the
indicator locks up and displays a message in three, one second displays: Z-Lock
Press Zero. The operator must press ZERO/ENTER to unlock the indicator.
Enable Off or On. Off is the default.
Time Use this to set the time value, in minutes, for this function. 60 minutes is
the default.
6.3.12 Beeper
Use this to enable or disable the beeper sound when you press keys. on is the default.
6.3.13 Num Scl
Use this to key in the number of scales attached to the scale (4 max). To access
settings for a scale use the SCALE key to display the proper scale number. Default is 1.
This completes the System menu.
If Auto = Off, the only way to update the indicator is to use the Manual update and
select Yes.
If the ADMIN password is changed, be sure to keep a record of it available for service
personnel or they may not be able to perform required maintenance when necessary.