TS5/TS7 Sensor Features
SMART MATRIX - 3-12 -
STOP [NO-NC]
It defines the operating mode of the Stop output:
STOP NO: The Stop output is normally open and it is connected to ground to signal an alarm condition.
STOP NC: The Stop output is normally closed (connected to ground) and it is opened to signal an alarm
condition.
ENABLE [NO-NC]
It defines the operating mode of the ENABLE input:
ENABLE NO: The ENABLE input is normally open and, if it is connected to ground you obtain the de-
activation of the Stop signal and the sensor exclusion.
When you release the ENABLE input, the sensor resumes the control after a wait time
corresponding to Delay Control (green LED flashing).
ENABLE NC: The ENABLE input is normally closed (connected to ground) and when it is released, you
obtain the de-activation of the Stop signal and the sensor exclusion.
Connecting again the ENABLE input to ground, the sensor resumes the control after a wait
time corresponding to Delay Control (green LED flashing).
Note: The ENABLE input is available only on TS5/TS7 sensors with 8 pin connector.
In case of sensors with a 4 pin connector, always program the ENABLE input as NO (Normally
Open).