50
8175
ENGLISH
TEST MENU
ENTER
ENTER
0......9
ENTER
0......9
ENTER
4.5.5 SIMULATION OF THE LEVEL OR TEMPERATURE
A level or temperature can be simulated within this function which allows the control
system to be tested whatever the conditions of the tank or vessel. The simulated
value influences the current ouput including the relays.
The units and decimal points selected within the engineering units are valid
within this function.
Press or to quit the simulation sub-menu and let the output be
automatically determined by the transmitter according to
the application.
Enter the temperature
value (°C of °F)
Enter the level, distance
or volume value
0......9
LEV / VOL
4.5.5
SIMUL
SIMUL
SIMUL
T° SIMUL
23.5 °C
30.2 °C
00.00 M
08.05 M