15
GasAlertMicroClip
Activating the Detector
Self-Test Pass
When the detector has passed all startup self-tests, it enters normal
operation. The LCD displays the ambient gas readings.
The detector automatically begins
• recording the peak (maximum) gas exposure,
• calculating the short-term exposure level (STEL), and
• calculating the time-weighted average (TWA) exposures.
Self-Test Fail
If the following error message displays after entering normal operation,
refer to Startup Troubleshooting
.
Battery Test
The battery is tested when the detector is activated and continuously
thereafter. See Specifications for Battery Runtimes.
• Battery power is continually displayed during normal operation. If
battery power is low,
L and flashes. The detector performs a
sequence of 10 rapid sirens and alternating flashes with 7 seconds
of silence in between (continues for 15 minutes).
• If battery power becomes critically low,
L and LOW BAT display.
The detector performs a sequence of 10 rapid sirens with 1 second
of silence in between (sequence reactivates seven times). The
detector then displays
OFF and the detector deactivates.
Note
If enabled, Confidence Beep and IntelliFlash automatically
deactivate during a low battery alarm. Refer to Confidence Beep
Backlight
The backlight automatically activates
• during startup,
• when the pushbutton is pressed (then deactivates after 5 seconds),
and
• when there is an alarm condition (unless Stealth is enabled).