61
GasAlertMicroClip
Specifications
Specifications
Instrument dimensions:
XT: 11.25 x 6.00 x 2.89 cm (4.4 x 2.4 x 1.1 in.)
XL-X3: 11.25 x 6.00 x 3.22 cm (4.4 x 2.4 x 1.2 in.)
Weight:
XT: 170 g (6.0 oz.)
XL: 190 g (6.7 oz.)
X3: 179 g (6.3 oz.)
Operating temperature: -4°F to +122°F (-20°C to +50°C) ()
Storage temperature: -40°F to +122°F (-40°C to +50°C)
Operating humidity: 0% to 95% relative humidity (non-condensing)
Alarm setpoints: May vary by region and are user defined. All setpoints
automatically display during the startup self-test
Detection range:
H
2
S: 0 – 100 ppm (1 / 0.1 ppm increments)
CO: 0 – 500 ppm (1 ppm increments)
O
2
: 0 – 30.0% vol. (0.1% vol. increments)
Combustible (LEL): 0% to 100% LEL (1% LEL increments) or 0.0% to
5.0% v/v methane
Alarm conditions: TWA alarm, STEL alarm, low alarm, high alarm,
multi-gas alarm, over limit (OL) alarm, low battery alarm, confidence
beep, automatic deactivation alarm
Audible alarm: 95 dB at 30 cm (1 ft.) (100 dB typical) variable pulsed
beeper
Visual alarm: Red light-emitting diodes (LED)
Display: Alphanumeric liquid crystal display (LCD)
Backlight: Activates when the pushbutton is pressed and deactivates
after 5 seconds; also activates during an alarm condition
Self-test: Initiated upon activation
Calibration: Automatic zero and automatic span
Oxygen sensor: Automatic span upon activation (enable/disable)
User field options: Startup message, Confidence Beep, latching
alarms, enable/disable safe display mode, oxygen measurement,
combustible sensor measurement, sensor disable, define calibration
interval, force calibration, calibration lock, force bump, define bump
interval, bump due lock, stealth mode, low alarm acknowledge, language
selection, enable/disable automatic oxygen calibration, enable/disable
auto zero at startup, define alarm setpoints, span concentration values,
define STEL calculation period, IntelliFlash, and Confidence Beep and
IntelliFlash Interval
Table 17: Battery Operating Time
1ppm =1 µmol/mol
XL-X3 XT
Typical Battery Life* 18 hours
Recharges in less
than 6 hours
10 hours
Recharges in less
than 4 hours
Cold Weather
Battery Life**
12 hours at -4°F / -
20°C
*Approximately 20% capacity loss is normal with lithium polymer
batteries after 500 charge cycles. Refer to the Operator’s Manual for
additional information.
**Battery is guaranteed to have 12 hour runtime during warranty period
under normal operating temperature of -4°F / -20°C to 122°F/50°C.