25
GasAlertMicroClip
User Options
Stealth Mode
When enabled, the backlight, visual alarms, and audible alarms are
disabled. displays continuously on the LCD.
During an alarm, the vibrator activates and readings display on the LCD.
The detector is shipped with Stealth Mode disabled.
Low Alarm Acknowledge
When enabled, the audible alarm can be deactivated during a low alarm
for the CO, H
2
S, and LEL sensors. The LED and visual alarm indicators
remain active until the alarm condition changes or the detector
deactivates.
Press
C to acknowledge the low alarm and deactivate the audible alarm.
Note
Low Alarm Acknowledge is not applicable to O
2
.
The detector is shipped with Low Alarm Acknowledge disabled.