Sensor Poisons and Contaminants
Several cleaners, solvents, and lubricants can contaminate and cause permanent damage to sensors. Before using cleaners, solvents, and lubricants
in close proximity to the detector sensors, read the following cautions and refer to the lists below.
a Caution
Use only the following BW Technologies by Honeywell recommended products and procedures:
Use water based cleaners.
Use non-alcohol based cleaners.
Clean the exterior of the detector with a soft, damp cloth.
Do not use soaps, polishes, or solvents.
Below are common products to avoid using around sensors.
Cleaners and Lubricants
Brake cleaners
Lubricants
Rust inhibitors
Window and glass cleaners
Dishsoaps
Citrus based cleaners
Alcohol based cleaners
Hand sanitizers
Anionic detergents
Methanol (fuels and antifreezes)