5. When charging is complete, the charging indicator stops flashing
and displays to indicate a full charge. Remove the charging
adapter and activate the detector.
If the battery indicator does not display, refer to Troubleshooting
.
6. Charge the battery after each workday.
Note
To reach full battery capacity, allow the battery to fully charge and
fully discharge three times.
Charging the detector in temperatures above 113°F (45°C) will
greatly reduce the number of charges the detector can accept.
The detector may be warm immediately following charging. This
is normal.
Replacing a Sensor or Sensor Filter
a Warning
To avoid personal injury, only use sensors that are
specifically designed for the detector. Refer to Replacement
Parts and Accessories.
Use proper ESD handling practices.
Each sensor has a high degree of resistance to common vapors and
gases. To clear a sensor, move the detector to a non-hazardous
environment and wait 10 to 30 minutes.
Do not expose a sensor to vapors of inorganic solvents such as
fumes from paint thinners, or organic solvents such as benzoic acids
and acrylic acids.
Ensure hands are clean or wear gloves before handling components.
To replace a sensor or sensor filter, refer to
•Table 1
4,
Figure 11
,
Figure 12
Figure 1
3, and
the following procedures.