PRODUCT MARKING AND BARCODE IDENTIFICATION
[TABLE OF CONTENTS]
[COMMAND LIST][INDEX][ESC][i][L][S]
B - Barcode Codabar
Barcode type: Codabar
Length: variable
Valid characters: numeric,
special characters: - $: /. +
and special start stop codes (A,B,C,D)
check digits: yes (Mod 16)
ratio oriented: yes
Each character of this barcode is built with 7elements (bars and spaces), where
the spaces do not contain information.Codabar ist mostly used in medical
environments for photo laboratories and libraries. The exact specifications are
described in the Norm: EN 798. The start and stop characters are additionaly
A,B,C or D.
B[:name;]x,y,r,CODABAR[+options], height,ne,ratio; text
CR
[+options] = +WSarea,
White Space area prints quiet zone markers around the bar
code, to make sure that the barcode can be read after printing.
This option is for design purposes only and should be removed
after the label is programmed.
+MODxx,
offers the possibility to add a modulo check digit to the
barcode.
+BARS,
Prints boundary lines above and below the barcode. Can be
used for a better readability. Helps to avoid incorrect readings
of this barcode.
Syntax:
xx

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CAB Apollo Series and is the answer not in the manual?

CAB Apollo Series Specifications

General IconGeneral
Print TechnologyThermal Transfer
Print Resolution203 dpi, 300 dpi, 600 dpi
Max Print Width104 mm
InterfacesUSB, Ethernet, RS232
Operating Temperature+5°C to +40°C
Dimensions240 mm

Related product manuals