SECTION 55 - ELECTRICAL SYSTEM 129
Foot
accelerator
signal out
of range
One second
alarm every
30 seconds
Accelerator
above 4.75 V
for 5 seconds
1011 VCM
Foot
accelerator
sensor -signal
above range
2Amber
Foot
accelerator
signal out
of range
One second
alarm every
30 seconds
Accelerator
under 0.25 V
for 5 seconds
1012 VCM
Foot
accelerator
sensor -signal
below range
2Amber
Foot
accelerator
signal out
of range
One second
alarm every
30 seconds
1013 VCM
Foot
accelerator
sensor -no
signal
2Amber
Foot
accelerator
signal out
of range
One second
alarm every
30 seconds
Accelerator
above 9 V for
5 seconds
1029 VCM
Foot
accelerator
sensor -
shorted high to
Vbat
2Amber
Foot
accelerator
signal out
of range
One second
alarm every
30 seconds
Accelerator
under 0.5 V
for 5 seconds
1030 VCM
Foot
accelerator
sensor -
shorted low to
Vbat
2Amber
Foot
accelerator
5 V supply
One second
alarm every
30 seconds
Accelerator
above 5.1 V
for 5 seconds
1023 VCM
Foot
accelerator
supply voltage
too high
2Amber
Foot
accelerator
5 V supply
One second
alarm every
30 seconds
Accelerator
under 4.9 V
for 5 seconds
1024 VCM
Foot
accelerator
supply voltage
too low
2Amber
Foot
accelerator
5 V supply
One second
alarm every
30 second
s
Accelerator
above 9 V for
5 seconds
1025 VCM
Foot
accelerator
supply shorted
high to Vbat
2Amber
Foot
accelerator
5 V supply
One second
alarm every
30 seconds
Accelerator
under 0.5 V
for 5 seconds
1026 VCM
Foot
accelerator
supply shorted
low
to ground
2Amber
Function Lamp Alarm Lamp Display
lamp
Condition DTC SA Description Priority Color