OPERATION & MAINTENANCE MANUAL STE35SR
96
the batteries increases, and the charging current of the batteries can gradually return to
normal.
During charging process, if the battery exhaust hole vent acid, should stop charging
immediately.
During charging process, check the battery eye color every hour. The battery is fully
charged when the eye turns green, then stop charging.
tarting Engine with Booster Cables
When starting the engine with a booster cable, do as follows:
Connecting and Disconnecting Booster Cables
When connecting the cables, never contact the positive (+) and negative (-) terminals.
When starting the engine with a booster cable, always wear safety glasses.
Be careful not to let the normal machine and
problem machine contact each other. This
prevents sparks from generating near the
battery which could ignite the hydrogen gas
given off by the battery. If hydrogen gas
explodes, it could cause serious injury.
Be careful not to make a mistake when
connecting a booster cable. In the last
connection (to the upper structure frame), a
spark will be caused, connect the cable to a
spot as far away from the battery as possible.
(Avoid the work equipment, however, because it is not a good conductor)
When removing the booster cable, exercise good care so that the booster cable clips may not
contact each other, or they contact the chassis.
NOTICE
The starting system for this machine uses 12V. For the normal machine, also use a 12V
battery.
The size of the booster cable and clip should be suitable for the battery size.
The battery of the normal machine must be the same capacity as that of the engine to be
started.
Check the cables and clips for damage or corrosion.
Make sure that the cables and clips are firmly connected.
Check that the lock levers and parking brake levers of both machines are in the LOCK
position.
Check that each lever is in the NEUTRAL position.
Booster Cable Connection
Keep the starting switch of the normal machine and
problem machine in the OFF position.
1. Connect the booster cable as follows, in the order
of the numbers marked in the diagram.
2. Connect the clip of booster cable (A) to the positive
(+) terminal of battery on the problem machine.
3. Connect the clip at the other end of booster cable
(A) to the positive (+) terminal of battery on the
normal machine.