123
Safety filter element is generally replaced at the same time when the main filter element is
replaced.
Do not remove the safety filter element unless it needs to be replaced.
Remove the safety filter element should be very careful, and the removal action should be
accurate in place, so that impurities are not easy to enter the engine.
After replacing the safety filter element, carefully check to ensure that the new safety filter element
is installed correctly.
Operation instructions for electric welding
The battery switch must be turned off before welding the machine or any device installed on
the machine.
Disconnect the battery cable and unplug the cable plug from the electronic controls before
any welding is performed on the machine.
Turn off the battery switch when disconnecting and reconnecting.
The grounding wire of welding equipment should be as close to the welding point as possible.
Remove all paint within a radius of at least 10 cm (4 inches) around the weld before welding.
Because heated paint gives off harmful gases.
All paints break down when heated and form large amounts of compounds that can cause pain,
irritation and health hazards if exposed to them for long periods of time.
In addition to health hazards, welding quality and strength will be damaged, and even lead to
future weld fracture. Therefore, do not directly on the paint surface welding.