EasyManua.ls Logo

Chroma 62150H-600S - FETCH Subsystem

Default Icon
238 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
5-36
5.6.2.4 FETCH Subsystem
1. FETCh:VOLTage?
Description: Measures the output of the Power Supply and returns the real time
voltage.
Query Syntax: FETCh:VOLTage?
Return Parameter: <NRf+> [Unit Volt]
Query Example: FETC:VOLT?
Return Example: 9.983100e+00
2. FETCh:CURRent?
Description: Measures the output of the Power Supply and returns the real time
current.
Query Syntax: FETCh:CURRent?
Return Parameter: <NRf+> [Unit Amp]
Query Example: FETC:CURR?
Return Example: 2.000000e-04
3. FETCh:POWer?
Description: Measures the output of the Power Supply and returns the real time
power.
Query Syntax: FETCh:POWer?
Return Parameter: <NRf+> [Unit Amp]
Query Example: FETC:POW?
Return Example: 5.000000e+03
4. FETCh:STATus?
Description: Returns the status code of the Power Supply’s state.
Query Syntax: FETCh:STATus?
Return Parameter: <Arg1><,><Arg2><,><Arg3>
<Arg1>: return warning message 0~65535, 0: no warning, use
binary for the rest and identify the cause of the error.
BIT 0: OVP
BIT 1: OCP
BIT 2: OPP
BIT 3: Remote Inhibit
BIT 4: OTP
BIT 5: FAN_LOCK
BIT 6: SENSE FAULT
BIT 7: SERIES FAULT
BIT 8: Reserved
BIT 9: AC FAULT
BIT 10: FOLD Back CV to CC
BIT 11: FOLD Back CC to CV
BIT 12: Reserved
BIT 13: Reserved
BIT 14: Reserved
BIT 15: Reserved
<Arg2>: ON|OFF output status at present
<Arg3>: CV or CC status at present