Remote Operation
5-37
5.6.2.5 MEASURE Subsystem
1. MEASure:VOLTage?
Description: Returns the voltage measured at the output of the Power Supply.
Query Syntax: MEASure:VOLTage?
Return Parameter: <NRf+> [Unit Voltage]
Query Example: MEAS:VOLT?
Return Example: 8.120000e+01
2. MEASure:CURRent?
Description: Returns the current measured at the output of the Power Supply.
Query Syntax: MEASure:CURRent?
Return Parameter: <NRf+> [Unit Amp]
Query Example: MEAS:CURR?
Return Example: 3.150000e+01
3. MEASure:POWer?
Description: Returns the power measured at the output of the Power Supply.
Query Syntax: MEASure:POWer?
Return Parameter: <NRf+> [Unit Amp]
Query Example: MEAS:POW?
Return Example: 5.000000e+03
5.6.2.6 PROGRAM Subsystem
1. PROGram: SELected
Description: Sets the executed program no.
Syntax: PROGram: SELected <NR1>
Parameter: 1 to 10
Example: PROG:SEL 10
Query Syntax: PROG:SEL? Returns the selected program number.
Return Parameter: <NR1>
Query Example: PROG:SEL?
Return Example: 10
2. PROGram:LINK
Description: Links a program to another program when it ends.
Syntax: PROGram:LINK <NR1>
Parameter: 0 to10 (0 is not linked)
Example: PROG:LINK 7
Query Syntax: PROG:LINK?
Return Parameter: <NR1>
Query Example: PROG:LINK?
Return Example: 7
3. PROGram:COUNT
Description: Sets the program file to be executed in series.
Syntax: PROGram:COUNT <NR1>
Parameter: 1 to 15000
Example: PROG:COUNT 7
Query Syntax: PROG: COUNT ?
Return Parameter: <NR1>
Query Example: PROG: COUNT ?
Return Example: 7