5.6.2.10 SYSTEM Subsystem
1. SYSTem:ERRor?
Description: Returns the Power Supply code and error message.
Query Syntax: SYSTem:ERRor?
Query Example: SYST:ERR?
Return Example: -203, “Data out of range”
Table 5-9
Code
Error Message
Code
Error Message
0
"No error"
-101
"Invalid character"
-102
"Syntax error"
-103
"Invalid separator"
-104
"Data type error"
-105
"GET not allowed"
-106
"Illegal parameter value"
-108
"Parameter not allowed"
-109
"Missing parameter"
-112
"Program mnemonic too long"
-113
"Undefined header"
-121
"Invalid character in number"
-123
"Numeric overflow"
-124
"Too many digits"
-131
"Invalid suffix"
-141
"Invalid character data"
-148
"Character data not allowed"
-151
"Invalid string data"
-158
"String data not allowed"
-202
"Setting conflict"
-203
"Data out of range"
-204
"Too much data"
-211
"Data stale"
-224
"Self-test failed"
-225
"Too many errors"
-226
"INTERRUPTED"
-227
"UNTERMINATED"
-228
"DEADLOCKED"
-229
"MEASURE ERROR"
-230
"Sequence overflow"
-231
"Sequence selected error"