Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
Figure 3-54
3.3.3.5.4 Setting PROTECTION for Parallel
The OCP and OPP [PROTECTION] settings in the MASTER unit in a parallel connection will
increase based on the number of units connected in parallel. They are indicated by ΣOCP
and ΣOPP for easy identification, as shown in Figure 3-55 below.
[ P R O T E C T I O N
]
O V P
= 6 0 0
.
0
_
V
∑
O C P
=
1 8 .
9 0
A
∑
O P P
=
1 0 5 0 0
.
0
W
R E M O T E I N H I B I T
=
D I S A B L E P U L L
=
H I G H
S A F E
T Y I N T
.
L O C K
= D I S A B L E P U L L
=
H I G H
E X T O N
/ O F F
=
D I S A B L E P U L L
=
H I G H
Figure 3-55
3.3.3.6 Setting Procedure for APG in Series or Parallel
3.3.3.6.1 Series Setting
The MAIN PAGE menu of the MASTER unit will display the following screen when connecting
two 62150H-600S DC Power Supplies for series operation and setting the APG option to APG
VSET/APG ISET = Vref(0-5V):
Figure 3-56
[
O U T P U T S E T U P
]
V L I M I T
:
M A X
= 6 0 0
.
0
_
V M I N
=
0
.
0
V
Σ
I L I M I T
:
M A X
=
2 5
.
0 0 A M I N
=
0
.
0
A
V S L E W R A T E
=
1 .
0 0 0 (
V
/
m S
)
Σ
I S L E W R A T E
=
I N F
. (
A
/ m S
)
V D C
_
R
=
6
.
0
V V D C
_
F =
6
.
0
V
▼
∑ V = 1 2 0 0
. 0 0 _ V I = 2 5. 0 0
A M S T O F F
0
. 0 0 0 0 V 0 . 0 0 0 0 A
0 . 0 W
A P G – V S A P G – I S