86
FORGE Batch Application Generator User Guide
5.1 INITIAL SETTINGS
The Initial property page features the following settings:
Settings
Default Value Remarks
Data Deletion Manual
Entry Options Show count Stay on the LCD for 600 ms
Key Click Tone 2
Backlight Turn off
Warning Beep Two beeps
Good Read Beep One beep
Vibrator Duration Off
Buzzer Volume LARGE_VOL Only for 8200/8400/8600
Reader Option CCD/Laser
Upload Method Cradle-IR
Note
Download Method Cradle-IR
Note
Bluetooth SPP is not available on the mobile
computer unless selected for downloading to
8061, 8360.
Baud Rate & Modem Speed 115200 bps
Note: For 8200/8400/8600/8700, the default upload/download port is RS-232.
5.1.1 DATA MANIPULATION
The [Data Manipulation] group box covers settings of “Data Deletion” and “Entry
Options” which are detailed in the following:
Data Deletion
Configures if the data should be automatically deleted from the mobile computer after it is
uploaded to a host computer.
It is set to “Manual” by default, which means the application template won’t delete the data from
the mobile computer after uploading but leaves it to your decision if to delete the data right after
the uploading completes. When the upload completes, you will be prompted if to delete the data. If
you decide not to delete the data right at the moment, you can always delete the data later by
selecting 3. Utilities | 3. Delete Data from the application main menu on the mobile computer.
Select “Automatic” to have the data automatically deleted from the mobile computer upon upload
completion. The data on the mobile computer is no longer available as soon as it is uploaded to a
host computer. You won’t see any data by using 3. Utilities | 2. Browse Data in the user
application main menu of the mobile computer; however, the data won’t be deleted if the uploaded
data type are lookup files.
If “No” is selected, the application template will skip the data deletion prompt upon completion of
upload. The data file(s) and lookup file(s) will remain on the mobile computer after they are
uploaded to a host computer. However, you can always select 3. Utilities | 3. Delete Data to
delete them later.
Entry Options

Table of Contents

Other manuals for CipherLab 8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CipherLab 8000 and is the answer not in the manual?

CipherLab 8000 Specifications

General IconGeneral
Operating SystemProprietary
Humidity5% to 95% non-condensing
Barcode ScannerLaser
ConnectivityRS-232
PortsRS-232
Weight (Extended)280g (with battery)
Storage Temperature-20°C to 60°C
Drop Specification1.2m

Related product manuals