137
Appendix II
CCD/Laser Scan Engine
Convert to UPC-A The UPC-E barcode will be expanded into UPC-A, and the
next processing will follow the settings configured for
UPC-A.
After conversion, the data follows UPC-A format and is
affected by UPC-A programming selections (e.g.
System Number, Check Digit).
No
Transmit Check Digit Decide whether to include the UPC-E check digit in the
data being transmitted.
Yes
Transmit System
Number
Decide whether to include the UPC-E System Number in
the data being transmitted.
No
Addon 2 / Addon 5 Decide whether to decode UPC-E with supplementals. No
UPC-E1 Disable
UPC-E1 Triple Check Decide whether to apply read redundancy to the UPC-E1
barcode. If true, the same UPC-E1 barcode has to be read
three times to make a valid reading.
This is helpful when the
barcode is defaced and
requires more attempts to read it successfully.
No
GS1 Formatting ---
GS1-128 (EAN128) Decide whether to enable GS1 formatting for GS1-128. Disable
GS1 DataBar Family Decide whether to enable GS1 formatting for GS1 DataBar
Family.
Disable
Field Separator Specify the field separator. No
Application ID Mark Specify the application ID mark character. No

Table of Contents

Other manuals for CipherLab 8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CipherLab 8000 and is the answer not in the manual?

CipherLab 8000 Specifications

General IconGeneral
Operating SystemProprietary
Humidity5% to 95% non-condensing
Barcode ScannerLaser
ConnectivityRS-232
PortsRS-232
Weight (Extended)280g (with battery)
Storage Temperature-20°C to 60°C
Drop Specification1.2m