19-14
Catalyst 2960 and 2960-S Switches Software Configuration Guide, Release 15.0(1)SE
OL-26520-01
Chapter 19 Configuring Flex Links and the MAC Address-Table Move Update Feature
Monitoring Flex Links and the MAC Address-Table Move Update
Rcv packet count this min : 0
Rcv threshold exceed count : 0
Rcv last sequence# this min : 0
Rcv last interface : Po2
Rcv last src-mac-address : 000b.462d.c502
Rcv last switch-ID : 0403.fd6a.8700
Xmt packet count : 0
Xmt packet count this min : 0
Xmt threshold exceed count : 0
Xmt pak buf unavail cnt : 0
Xmt last interface : None
Beginning in privileged EXEC mode, follow these steps to configure a switch to get and process MAC
address-table move update messages:
To disable the MAC address-table move update feature, use the no mac address-table move update
receive configuration command. To display the MAC address-table move update information, use the
show mac address-table move update privileged EXEC command.
This example shows how to configure a switch to get and process MAC address-table move update
messages:
Switch# configure terminal
Switch(conf)# mac address-table move update receive
Switch(conf)# end
Monitoring Flex Links and the MAC Address-Table
Move Update
Table 19-1 shows the privileged EXEC commands for monitoring the Flex Links configuration and the
MAC address-table move update information.
Command Purpose
Step 1
configure terminal Enter global configuration mode.
Step 2
mac address-table move update receive Enable the switch to get and process the MAC
address-table move updates.
Step 3
end Return to privileged EXEC mode.
Step 4
show mac address-table move update Verify the configuration.
Step 5
copy running-config startup config (Optional) Save your entries in the switch startup
configuration file.
Table 19-1 Flex Links and MAC Address-Table Move Update Monitoring Commands
Command Purpose
show interfaces [interface-id] switchport
backup
Displays the Flex Link backup interface configured for an interface or all the
configured Flex Links and the state of each active and backup interface (up
or standby mode). When VLAN load balancing is enabled, the output
displays the preferred VLANS on Active and Backup interfaces.
show mac address-table move update Displays the MAC address-table move update information on the switch.

Table of Contents

Other manuals for Cisco CATALYST 2960

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco CATALYST 2960 and is the answer not in the manual?

Cisco CATALYST 2960 Specifications

General IconGeneral
ManageableYes
StackingNo
ModelCatalyst 2960 Series Switches
Power over Ethernet (PoE)Available on some models (IEEE 802.3af)
VLANs255 active VLANs
FeaturesQoS
Operating Temperature32 to 113°F (0 to 45°C)
Relative Humidity10% to 85% non-condensing
Power ConsumptionVaries by model (30W to 400W)

Related product manuals