Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.0
78-18663-01
Chapter 2 Alarm Troubleshooting
Alarm Procedures
Step 4 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC
(1-800-553-2447).
2.7.167 NON-CISCO-PPM
Default Severity: Not Reported (NR), Non-Service-Affecting (NSA)
SDH Logical Object: PPM
The Non-Cisco PPM Inserted condition occurs when a PPM that is plugged into a card’s port fails the
security code check. The check fails when the PPM used is not a Cisco PPM.
Clear the NON-CISCO-PPM Condition
Step 1 Obtain the correct Cisco PPM and replace the existing PPM with the new one.
Step 2 If the condition does not clear, log into the Technical Support Website at
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC
(1-800-553-2447).
2.7.168 NOT-AUTHENTICATED
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SDH Logical Object: SYSTEM
The NOT-AUTHENTICATED alarm is raised by CTC (not by the NE) when it fails to log into a node.
This alarm only displays in CTC where the login failure occurred. This alarm differs from the
“INTRUSION-PSWD” alarm on page 2-76 in that INTRUSION-PSWD occurs when a user exceeds the
login failures threshold.
Note NOT-AUTHENTICATED is an informational alarm and is resolved when CTC successfully logs into the
node.
2.7.169 OOU-TPT
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SDH Logical Objects: VCTRM-HP, VCTRM-LP
The Out of Use Transport Failure alarm is a VCAT member alarm. (VCAT member circuits are
independent circuits that are concatenated from different time slots into a higher-rate signal.) This
condition is raised when a member circuit in a VCAT is unused. It occurs in conjunction with the
“VCG-DEG” alarm on page 2-144.

Table of Contents

Other manuals for Cisco CTX2500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco CTX2500 and is the answer not in the manual?

Cisco CTX2500 Specifications

General IconGeneral
BrandCisco
ModelCTX2500
CategoryNetwork Card
LanguageEnglish

Related product manuals