2-27
Cisco ONS 15310-MA SDH Troubleshooting Guide, Release 9.0
78-18663-01
Chapter 2 Alarm Troubleshooting
Alarm Procedures
Step 7 If the alarm does not clear, log into the Technical Support Website at
http://www.cisco.com/cisco/web/support/index.html for more information or call Cisco TAC
(1-800-553-2447).
2.7.17 AUD-LOG-LOW
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SDH Logical Object: NE
The Audit Trail Log Low condition occurs when the audit trail log is 80 percent full.
Note AUD-LOG-LOW is an informational condition and does not require troubleshooting.
2.7.18 AUTOLSROFF
The AUTOLSROFF ALARM is not used in the ONS 15310 platforms in this release. It is reserved for
development.
2.7.19 AUTORESET
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SDH Logical Object: EQPT
The Automatic System Reset alarm occurs when you change an IP address or perform any other
operation that causes an automatic card-level reboot. AUTORESET typically clears after a card reboots
(up to ten minutes).
Resets performed during a software upgrade also prompt the condition. This condition clears
automatically when the card finishes resetting.
Clear the AUTORESET Alarm
Step 1 Determine whether additional alarms are present that could have triggered an automatic reset. If so,
troubleshoot these alarms using the applicable section of this chapter.
Step 2 If the reporting card is an ML-100T-8, CE-MR-6, or CE-100T-8 card and automatically resets more than
once a month with no apparent cause, complete the “Physically Replace a Card” procedure on
page 2-153.
Caution Always use the supplied electrostatic discharge wristband when working with a powered
ONS 15310-MA SDH.
Note When you replace a card with the identical type of card, you do not need to make any changes
to the database.