Group 19, Motor Controls
19-4-2 • GEX Factory Control Settings SM 765, Nov ’06
PARAMETER CHANGE Turtle Mode Economic Mode Normal Mode Power Mode
SET MODEL
CONNECTED TO 3 (Master) 3 (Master) 3 (Master) 3 (Master)
ADJUSTMENTS
SET POT BRK MIN 0.5 V0.5 V0.5 V0.5 V
SET POT BRK MAX 4.5 V4.5 V4.5 V4.5 V
SET BATTERY TYPE 80V 80V 80V 80V
ADJUST BATTERY
MAX STEER RIGHT
MAX STEER LEFT
SET STEER 0-POS.
SET STEER RIGHT 83 Degrees 83 Degrees 83 Degrees 83 Degrees
SET STEER LEFT 60 Degrees 60 Degrees 60 Degrees 60 Degrees
THROTTLE 0 ZONE 1% 1% 1% 1%
THROTTLE X POINT 54% 54% 54% 54%
THROTTLE Y POINT 47% 47% 47% 47%
ADJUSTMENT #04
130
130 130 130
MOTOR SHUTDOWN
145
145 145 145
ADJUSTMENT #02 LEVEL = 4 LEVEL = 4 LEVEL = 4 LEVEL = 4
ADJUSTMENT #01 LEVEL = 4 LEVEL = 4 LEVEL = 4 LEVEL = 4
ADJUSTMENT #03 20% 20% 20% 20%
MAIN CONT. VOLT. 80 V 80 V 80 V 80 V
AUX OUTPUT VOLT. 36 V 36 V 36 V 36 V
MAINTEN. RESET OFF OFF OFF OFF
MAINTENANCE NONE NONE NONE NONE
MAINTENANCE TIME 250 250 250 250
1X10000 HOURS 0 0 0 0
1X1000 HOURS 0 0 0 0
1X100 HOURS 0 0 0 0
1X10 HOURS 0 0 0 0
1X1 HOURS 0 0 0 0
DISP. GEAR RATIO 42 42 42 42
SLAVE (DUAL AC2)
SET MODEL
CONNECTED TO 4 (Slave)4 (Slave)4 (Slave)4 (Slave)
ADJUSTMENTS
SET BATTERY TYPE 80V 80V 80V 80V
ADJUST BATTERY
AUX OUTPUT VOLT. 12V 12V 12V 12V
PUMP (AC2)