EasyManuals Logo

CMC electronic Esterline CMA-5024 User Manual

CMC electronic Esterline CMA-5024
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #186 background imageLoading...
Page #186 background image
INSTALLATION MANUAL
CMA-5024 GLSSU
This document includes Proprietary Information and shall not be reproduced or communicated to third party
without prior written permission by CMC Electronics Inc.
Page E.23
November 21, 2008
(11) APD #10: ARINC-743A-4 Configuration with Automatic mode transition and label 304 input
Navigation connector J1 ARINC 743A-4 compatible, plus automatic mode transition to SBAS
PA when an approach is selected. Supplementary command summary label 304 is
accepted. Otherwise identical to APD #0.
(12) APD #11: Custom SBAS measurement block labels
Navigation connector J1 ARINC 743A-4 compatible, plus automatic mode transition to SBAS
PA when an approach is selected. Supplementary command summary label 304 is
accepted. Non-standard measurement block labels for SBAS correction data are output.
Otherwise identical to APD #10.
(13) APD #12: Custom PRAIM labels
Navigation connector J1 ARINC 743A-4 compatible, plus automatic mode transition to SBAS
PA when an approach is selected, plus non-standard PRAIM request labels. Otherwise
identical to APD #10.
(14) APD #13: Custom PRAIM and SBAS measurement block labels
Navigation connector J1 ARINC 743A-4 compatible, plus automatic mode transition to SBAS
PA when an approach is selected, plus non-standard PRAIM request labels. Non-standard
measurement block labels for SBAS correction data are output. Otherwise identical to APD
#11.
(15) APD #14: Triple GLSSU
Configured for a triple GLSSU installation. Same as APD #0 except: Automatic SBAS PA
mode; Synchronized Approach Selection; CRC labels (306 & 307).
(16) APD #15: ARINC-743A-4 Configuration with Automatic mode transition and label 304 input
Navigation connector J1 ARINC 743A-4 compatible, plus automatic mode transition to SBAS
PA when an approach is selected. Supplementary command summary label 304 is
accepted. SBAS corrected measurements are output on the measurement block. Otherwise
identical to APD #10.
34-52-81-1
The document reference is online, please check the correspondence between the online documentation and the printed version.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CMC electronic Esterline CMA-5024 and is the answer not in the manual?

CMC electronic Esterline CMA-5024 Specifications

General IconGeneral
BrandCMC electronic
ModelEsterline CMA-5024
CategoryAccessories
LanguageEnglish

Related product manuals