INSTALLATION MANUAL
CMA-5024 GLSSU
This document includes Proprietary Information and shall not be reproduced or communicated to third party
without prior written permission by CMC Electronics Inc.
Page 27
November 21, 2008
CHARACTERISTICS SPECIFICATION
ENVIRONMENTAL SPECIFICATIONS
cont’d
Voltage Spike DO-160E Section 17, Category A
Audio Frequency Conducted
Susceptibility Power Inputs
DO-160E Section 18, Category Z
Induced Signal Susceptibility DO-160E Section 19, Category ZC
Radio Frequency Susceptibility DO-160E Section 20, Category YY*
Emission of Radio Frequency Energy DO-160E Section 21, Category M
Lightning Induced Transient
Susceptibility
DO-160E Section 22, Category A3J33***
Multiple bursts at 360 V / 12 A****
Lightning Direct Effects DO-160E Section 23, Category X
Icing DO-160E Section 24, Category X
Electrostatic Discharge DO-160E Section 25, Category A
Fire, flammability DO-160E Section 26, category X
* * Frequencies from 1500 MHz to 1640 MHz are tested at a Category Rating S (1 V/m).
** The test limit of 36 VDC exceeds the DO-160E category requirement for normal operation of 30.3
VDC.
*** Power lines are at Category A3G33.
**** The test limit exceeds the DO-160E category requirement for multiple bursts of 360V/6A.
Figure 11. GLSSU Environmental Specifications (Sheet 2 of 2)
The document reference is online, please check the correspondence between the online documentation and the printed version.